UV-2300C Wall mounted ozone concentration analyzer

高浓度臭氧检测仪

Detection principle: UV dual optical path absorption method, used for real-time detection of ozone generator outlet concentration or tail gas ozone concentration detection.
Measurement range: 0-400g/Nm3; 0-300g/Nm3 ;0-200g/Nm3
Product features: patented technology, with automatic zero calibration function, dual optical path UV absorption method principle, foreign long life UV LED light source, continuous operation, ensuring the stability of the detection concentration. Waterproof and dust proof

附件

产品详情

Technical parameters

Model: UV-2300C

Measuring range: 0-300g/Nm3

Optional range: 0-400g/Nm3; 0-200g/Nm3 0-100g/Nm3 0-50g/Nm3 0-10000ppm

Light source life: about 30000-50000 hours;

Sampling method: positive pressure sampling, negative pressure sampling (optional);

Display interface: 4.3 inch touch screen operation interface (optional 7 inch touch screen);

Content interface: ozone concentration, temperature, pressure; (Customizable data recording)

Auxiliary functions: temperature compensation, pressure compensation;

Display unit: g/Nm3, mg/NL,% WT optional;

Display resolution: 0.01g/Nm3;

Gas flow: 0.5L ± 0.2L/min;

Input pressure:<0.1MPa;

Concentration error: 0.5% FS;

Linear error: 0.5% FS

Zero drift:<± 0.3%. FS;

Response time: signal 0.03 seconds, display 0.3 seconds;

Ambient temperature: - 20~50 ;

Pipeline interface mode: quick screwing (stainless steel);

Diameter of series connection sample: Φ 8 (8mm * 6mm) (optional);

Bypass sampling diameter: Φ 66mm*4mm);

Communication mode: RS-485;

Output mode: 4-20mA (active);

Power supply: AC 110-220V;

Size: 230mm (height)× 330mm (width) × 150mm( depth);

Note: 1mg/L=1g/m3=467PPM;

Free warranty: 24 months (host sensor);

Note: Standard configuration (built-in): anti-corrosion flow-meter, ozone exhaust gas destructor, ozone intake (dust) filter.






 

Product features:

Measurement features: patented technology, dual optical path UV absorption method principle, foreign long life UVLED light source, continuous operation, ensuring the stability of the detection concentration.

Test method: dual optical path UV optical absorption method, long life light source system, ensuring measurement accuracy.

Real-time calibration: With an automatic zero calibration function, the system will automatically complete the zero calibration operation when ozone is introduced.

Measurement principle: Accurate measurement based on Lambert Beer's law and the principle of photometric absorption.

Light source system: Foreign long-life UVLED light source system, with a two-year free warranty.

Usage: It is rainproof and can be installed indoors and outdoors. It is equipped with waterproof power supply and signal terminals.

Light cell system: Separate light cell and gas chamber structure, no leakage, high pressure resistance, and resistance to large flow sampling gas impact.

Intelligent compensation: Built-in temperature and pressure compensation with display, with automatic light source compensation function.

Operation mode: The user can select manual and automatic zero calibration based on the operation status, and can set the automatic zero calibration time.

Display unit: g/Nm3, mg/NL, WT% can be customized and optional.

Data display: Color touch screen, customizable data recording function.

Output function: 4-20mA, RS485 communication, two groups of alarm point output, electronic flow-meter input, etc.

Standard configuration: anti-corrosion flow-meter, ozone exhaust gas destructor, ozone intake filter.

 

Patent information of Shandong Shandong ZHIPRER M&C Tech Cor. LTD. involved in and adopted by this ozone concentration analyzer:

Patent name: An ozone concentration analyzer device with automatic zero calibration function

Patent name: Ozone concentration analyzer optical cell absorption chamber device

Patent name: An ozone concentration analyzer with gas split flow automatic zero calibration function

The above patents are proprietary intellectual property rights owned by the company, and patented products that have been intensively researched and developed must be prosecuted for counterfeiting

UV-2300C Wall mounted ozone concentration analyzer
Detection principle: UV dual optical path absorption method, used for real-time detection of ozone generator outlet concentration or tail gas ozone concentration detection.
Measurement range: 0-400g/Nm3; 0-300g/Nm3 ;0-200g/Nm3
Product features: patented technology, with automatic zero calibration function, dual optical path UV absorption method principle, foreign long life UV LED light source, continuous operation, ensuring the stability of the detection concentration. Waterproof and dust proof
长按识别二维码查看详情
金年会金字招牌信誉至上
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询内容:


你还没有添加任何产品

加入成功

Copyright @ 2020 金年会|金年会·jinnian(金字招牌)信誉至上  All Rights Reserved   京ICP证000000号     金年会金字招牌信誉至上 鲁公网安备 37030302000842号
金年会持有9类注册商标品牌:爱迪尔、 爱迪尔仪器、  爱迪尔仪表、  爱迪尔测控、 爱迪尔设备、 爱迪尔分析仪、 爱迪尔检测仪、爱迪尔臭氧、 爱迪尔科技、  爱迪尔技术、 爱迪尔传感器、 爱迪尔测试仪、 

爱迪尔装置、 爱迪尔浓度仪、 爱迪尔精密仪器、 爱迪尔监测仪、  爱迪尔测量、 爱迪尔计量、 AIDIER、  ADIER、 USIDEAL、  ZHIPRER、 UVOZ、 IDALER、 ZUNKUN、 未经许可不得擅自使用。

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了